2-17
Note 1. Parameter settings canbe usedtoselect variousfunctions formulti-function inputs1
to 7, multi-function contact outputs, and multi-function photocoupler outputs. The
functions in parentheses are the default settings.
Note 2. NPN is the default setting for these terminals. Wire them by providing a common
ground. No external power supply is required.
Note 3. To provide an external power supply and wire the terminals througha commonposi-
tive line, set SW1 to PNP and use a 24 V DC ±10% external power supply.
Note 4. When multi-function analog outputs are used for pulse train outputs, they can be di-
rectly connected to the pulse train inputs at other 3G3MV-series Inverters for simple
synchronization or other applications.
H Selecting Input Method
·SwitchesSW1andSW2, both ofwhichare locatedabovethecontrol circuitterminals,
are used for input method selection.
Remove the front cover and optional cover to use these switches.
Selectors
Control circuit
terminal block
Design Chapter 2