82
Actuator 2 Stop
Current
0 – 12 A The driver turns off if the current exceeds this value.
Actuator 2 Stop
Time
3 – 120 s The driver turns off if it runs longer than this period of time.
Bulb Voltage 0 – 24 V
Determines the voltage of the bulbs. In accordance with the Road
Trafc Licensing Regulations (StVZO), the bulbs are kept at a constant
voltage for consistent brightness.
Light ½
Voltage
On/Off Permits operating the headlights with half of the bulb voltage.
Min Light Cur-
rent
0 – 3 A
Sets the minimum current for the headlights; an error is recognised
below this current.
Indicator ½
Voltage
On/Off
Permits operating the direction indicator lights with half of the bulb
voltage.
Min Indicator
Current
0 – 3 A
Sets the minimum current for the direction indicator lights; an error is
recognised below this current.
Indicator Time-
out
0 – 30 s
Sets the maximum time a direction indicator remains active before
it is turned off automatically. A value of 0 deactivates this function.
Peak Current
Limit
5 – 75 A Delivers a motor current boost. Sets the motor current limit effective
for the Peak Current Time.
Peak Current
Time
0 – 60 s
Sets the effective time for the Peak Current Limit motor current limit.
Drive Current
Limit
5 – 60 A Sets the motor current limit for normal driving.
Regen Current
Limit
5 – 75 A Sets the motor current limit for regenerative braking.