28.4 Display current consumption in unit
(H5/A4)
Control unit: The total current consumption (incl. the charging
current at 24 V) for the control unit when it is connected to the mains
(230 V AC), i.e. this function is not working by battery backaup.
NOTE! No or very small current consumption will not be presented
correctly / precisely since the accuracy is ± 5 mA.
Charging: The battery charging current.
Low capacity voltage difference: During the battery capacity check
the voltage is measured with and without a resistor. A difference
between these two voltages > 2100 mV will result in a "Low battery
capacity" fault. This is checked every 4
th
hour.
This window will not be visible until 4 hours after the c.i.e. is powered and
the batteries have to be connected.