PBX Parameters
Specifies how the system will initiate and control call transfers, setup outgoing calls, and control message
waiting lamps on extensions.
Name Description Value Range Links
PBX Environment—
Operator Transfer
Sequence (Up to 16
digits / [0-9 * # D R F
T X , ;])
Specifies the
sequence for
transferring calls
to an operator’s
extension.
Max. 16 digits consisting of 0–9, , #
and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialling
0–9, , #: Dial Code
PBX Environment—
Extension Transfer
Sequence (Up to 16
digits / [0-9 * # D R F
T X , ;])
Specifies the
sequence for
transferring calls
to any extension
except an
operator’s
extension.
Max. 16 digits consisting of 0–9, , #
and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialling
0–9, , #: Dial Code
PBX Environment—
Alternate Extension
Transfer Sequence
(Up to 16 digits / [0-9 *
# D R F T X , ;])
Specifies the
sequence for
transferring calls
to extensions in
the Alternate
Extension Group.
Max. 16 digits consisting of 0–9, , #
and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialling
0–9, , #: Dial Code
Feature
Manual
References
3.2.1.1
Alternate
Extension
Group
24.4 UM Configuration—[5-4] System Parameters—Parameters
642 PC Programming Manual