4-28 System Programming
[203]-[204] 4.2 System Programming
Assigns the length of time for the Pickup Dialing feature. If the telephone user lifts the
handset, the programmed party is called automatically when the timer expires. This delay
gives the user an opportunity to enter numbers before automatic dialing occurs.
Default 3 seconds
• Feature Reference
Section 3, Features
Pickup Dialing
(1/2/3/4 sec)
Assigns the start time of a conversation either immediately after an outside (CO) line is
seized or after dialing. This corresponds to the length of the conversation displayed on the
LCD and printed on the printer (SMDR).
Default 10 seconds after dialing
• If reverse signal detection is enabled in program [424] “Reverse (Polarity) Circuit
Assignment”, the system will automatically start the timer immediately after an external
party answers a call.
• Feature References
Section 3, Features
Polarity Reverse Detection, Station Message Detail Recording (SMDR)