System Programming 4-51
4.2 System Programming [418]-[419]
Selects which outside (CO) line can be seized automatically when an extension user dials the
Automatic Line Access number (9 or 0) assigned in program [121] “Automatic Outside (CO)
Line Access Number Selection”.
* Outside (CO) line number: 1 through 6 / (All outside lines)
Default All outside (CO) lines – Enable
Feature References
Section 3, Features
Automatic Outside (CO) Line Access Number, Outside Calling
outside line no.*
[419] Automatic Designated Outside (CO) Line Access
9
1
4
(1
···
6/ )
NEXT
SELECT
(Enable/
Disable)
END
To continue
NEXT
PREV
or
To continue
STORE
Assigns the length of the flash time. If your system is installed behind a host PBX, External
Feature Access is necessary to obtain its services. To enable it, select the required flash
signal sending time for an outside (CO) line.
* Outside (CO) line number: 1 through 6 / (All outside lines)
Default All outside (CO) lines – 600 milliseconds
Feature References
Section 3, Features
External Feature Access, Flash
[418] Flash Time
8
1
4
NEXT
SELECT
(80/100/160/
300/600/900/
1200 ms)
END
outside line no.*
(1
···
6/ )
To continue
NEXT
PREV
or
STORE
To continue
SELECT
SELECT