Powering-up the Unit
1. Apply the 3-phase supply to the 890SD Standalone Drive.
2. Select LOCAL mode operation:
The Keypad will display the Remote Setpoint parameter (%).
3. You MUST carry out an Autotune if you intend to use the drive in Sensorless Vector Fluxing Mode
or Closed-Loop Vector Mode - go to page 4-
43. If you are using the drive in Volts/Hz Mode (Open-
Loop Drive) an Autotune is not necessary - go to page 4-
48.
REMOTE
LOCAL
Hold the Stop key down until
the display spells
Release the key to display
the previous menu
for example,Local Setpoint