EasyManua.ls Logo

Parker 890SD - Electrical Ratings: 890 CS Frame D, 500 V

Parker 890SD
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications
Page E-8 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Electrical Ratings: 890CS Frame D, 500V
Output current must not be exceeded under steady state operating conditions.
FRAME D : 108A AC rms Input Current (nominal power 60kW)
Model Number
890CS/5/0108D
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 108
Continuous RMS Output Current
A 135
Output Power
30kW/40HP 60kW 90HP 75kW
Power Loss
W 300 300 300 300
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 75 75 75 75
Input Bridge I
2
t
A
2
s 108,000
Prospective Short Circuit Current
kA 100
FRAME D : 162A AC rms Input Current (nominal power 90kW)
Model Number
890CS/5/0162D
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 162
Continuous RMS Output Current
A 200
Output Power
45kW/60HP 90kW 135HP 110kW
Power Loss
W 500 500 500 500
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 100 100 100 100
Input Bridge I
2
t
A
2
s 128,000
Prospective Short Circuit Current
kA 100

Table of Contents

Other manuals for Parker 890SD

Related product manuals