EasyManua.ls Logo

Parker 890SD - Selecting Local or Remote Mode

Parker 890SD
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Keypad
Page 8-8 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Selecting Local or Remote Mode
The unit can operate in one of two ways:
Remote Mode: Remote control using digital inputs
Local Mode: Local control using the Keypad
Local control keys are inactive when Remote mode is selected.
You can change between local and remote mode from any point on the MMI.
Note You can only change between Local and Remote Mode when the unit is “stopped” (when the DC link is
powered-down).
Remote to Local Mode:
Local to Remote Mode:
The ENABLE input (DIGIN2) must be inactive to effect this change.
REMOTE
LOCAL
Hold the Stop key down until
the display spells
Release the key to display
the previous menu
for example,Local Setpoint
REMOTE
LOCAL
Release the key to display
the previous menu
Hold the Stop key down until
and are removed from the display

Table of Contents

Other manuals for Parker 890SD

Related product manuals