Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page E-27
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Cabling Requirements for EMC Compliance
Power Supply
Cable
Motor Cable
External AC Supply
EMC Filter to Drive
Cable
Brake
Resistor
Cable
Signal/Control
Cable
Cable Type
(for EMC Compliance)
Unscreened
Screened/
armoured
Screened/
armoured
Screened/
armoured
Screened
Segregation
From all other
wiring (clean)
From all other wiring (noisy)
From all other
wiring (sensitive)
890xx/2/…
Length Limitations
Unlimited
25 meters To achieve
EN61800-3 Table 9
restricted distribution
25 metres 25 metres
890xx/5/…
Unfiltered
Length Limitations
Unlimited
25 meters To achieve
EN61800-3 Table 11
I<100 A
25 metres 25 metres
890xx/x/…
Length Limitations
With External AC
Supply EMC Filter
Unlimited
50 metres To achieve
EN61800-3 Table 9
restricted distribution
0.3 metres
25 metres
25 metres
Screen to Earth
Connection
Both ends Both ends Both ends Drive end only
Output Choke 300 metres maximum
* Maximum motor cable length under any circumstances