EasyManua.ls Logo

Parker 890SD - OPERATOR MENU

Parker 890SD
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
Page D-74 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
OPERATOR MENU
SETUP::MENUS::OPERATOR MENU
These function blocks, 1 to 32, are used to configure the Operator menu. This feature provides quick access to frequently used
parameters. Any parameter may be “promoted” to the Operator menu, and the parameter is then automatically saved on power-
down. In addition, parameters displayed in the Operator menu may be given a different name, and may be rescaled for display
using the DISPLAY SCALE function blocks.
PREF 32.xx is OPERATOR MENU 1, PREF 33.xx is OPERATOR MENU 2, ….. PREF 64.xx is OPERATOR MENU 32.
Parameter Descriptions
PARAMETER
PREF: 33.01 to 64.01 Default: 0 Range: 0 to 1999
Enter the parameter to be displayed in the Operator menu. The parameter may be selected by first choosing the block that the
parameter is within, then choosing the parameter itself.
NAME
PREF: 33.02 to 64.02 Default: Range: max length is 16 chars
Enter your customised parameter name, the maximum length is 16 characters. If this name is left blank, then default parameter
name will be used.
SCALING
PREF: 33.03 to 64.03 Default: NONE Range: Enumerated - see below
Selects a DISPLAY SCALE function block to be applied to the value of PARAMETER.
Enumerated Value : Scaling
0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4

Table of Contents

Other manuals for Parker 890SD

Related product manuals