EasyManua.ls Logo

Parker 890SD - 890 CD;SD 4-Q Regen AFE Applications; Introduction

Parker 890SD
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating the Drive
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 7-23
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
890CD/SD 4-Q Regen AFE Applications
Introduction
A 4-Q REGEN (4 Quadrant Regenerative) control mode is available on all 890CD Common Bus Drives
and 890 Standalone Drives, provided that :
the drive uses Software Version 1.x (1.8 or greater), or Software Version 3.x
(Software Version 2.x does not support 4Q mode)
AND
for Frame B-D: the SETUP::MISCELLANEOUS::EMC CAPACITORS parameter is set to (1)
NOT CONNECTED
for Frame E-K: the drive displays “/007” in Block 12 of the (Europe) Product Code indicating that
Special Option 7 is applied (“Y” cap disconnection)
IMPORTANT All drives in a common DC link scheme using a 4-Q Regen front-end MUST have their internal EMC
filter "Y" caps to earth (PE) removed.
The 4-Q REGEN control mode allows a single 890 to act as a 4-Q power supply unit that is capable of
drawing (motoring) and supplying (regenerating) sinusoidal, near-unity power factor current from the
supply.
The output from the 4-Q Regen drive acts as a DC supply which is used to power other drives on a common
DC Bus system.