Operating the Drive
Page 7-32 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
A Single Motor System
890 Drive
(4-Q Power Supply)
DC+
DC
-
U
V
W
720V
Boosted Common
DC Link Supply
External Pre -
Charge
Control
DC
AC Motor
Motor Load
DC
-
DC+
U
V
W
890 Drive
Link Fuses
4-Q Active Front End
The simplest configuration for 4-Q Regen control is a single 890 Regen drive acting as the unity power
factor supply, connected via the DC link to another 890 driving the application.
Applications of single motor 4-Q Regen systems include :
Hoist and Elevators
Dynamometer test rigs
Unwind Stands
Installations that would otherwise require a Harmonic Power Filter
In this system, the two 890 drives are matched in power. The 4-Q Regen drive supplies the full motoring
and regenerating requirement of the load.