Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page D-69
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Parameter Descriptions
MUTUAL INDUC
PREF: 27.16 Default: 135.02 mH Range: 0.00 to 3000.00 mH
This parameter contains the motor model per-phase mutual (magnetising) inductance as determined by Autotune.
ROTOR TIME CONST
PREF: 27.17 Default: 136.75 ms Range: 10.00 to 30000.00 ms
This parameter contains the motor model rotor time constant as determined by Autotune.