Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page D-71
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Parameter Descriptions
DIST TO MASTER
PREF: 124.06 Default: —.xxxx Range: —.xxxx
This diagnostic displays the distance (1.0 = 1 load mechanical revolution) between the load shaft position and the Master
Position + Total Offset position.
ACTIVE
PREF: 124.08 Default: FALSE Range: FALSE / TRUE
This diagnostic is TRUE to indicate Move to Master is active.
STATE
PREF: 124.09 Default: 1 Range: See below
This diagnostic indicates the state of the Move to Master move.
Enumerated Value : State
0 : RESET the move to master is in a reset state and cannot be used.
1 : READY the move to master is ready to be enabled
2 : POS AQUIRE the target position for the move is being acquired
3 : ALIGN the move is active
4 : DONE the move to master is complete