Programming
Page D-80 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Functional Description
When in Phase control, the Phase Inch function block may be used to advance or retard the relative position on the slave axis
with respect to the master axis. This is achieved by feeding extra counts into the position calculator at a rate given by RATE in
units per second.
ADVANCE and RETARD are usually linked to operator controlled, momentary-action push buttons