Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page D-85
8
9
10
11
B
C
D
1
2
3
4
5
6
7
E
Parameter Descriptions
POSITION
PREF: 120.05 Default: 0.0000 Range: 0.0000 to 1.0000
The absolute position demand (1.0 = 1 load mechanical revolution).
VELOCITY
PREF: 120.06 Default: 1.00 % Range: 0.10 to 300.00 %
This parameter defines the maximum velocity of the move, set in percent of maximum load speed.
ACCELERATION
PREF: 120.07 Default: 1.00 % Range: 0.01 to 3000.00 %
This parameter defines the maximum acceleration of the move, set in percent of maximum load speed per second.
ABS POSITION
PREF: 120.08 Default: —.xxxx Range: —.xxxx
This diagnostic displays the absolute position feedback (1.0 = 1 load mechanical revolution).
ACTIVE
PREF: 120.10 Default: FALSE Range: FALSE / TRUE
This diagnostic is TRUE to indicate Move Abs is active (i.e. the position demand is being provided by this block)
DONE
PREF: 120.11 Default: FALSE Range: FALSE / TRUE
This diagnostic is TRUE to indicate the last Move Abs enabled has completed.
STATE
PREF: 120.12 Default: 1 Range: See below
This diagnostic indicates the state of the Move Abs move.
Enumerated Value : State
0 : RESET the move to master is in a reset state and cannot be used.
1 : READY the move Abs is ready to be enabled
2 : POS AQUIRE the target position for the move is being acquired
3 : ALIGN the move is active
4 : DONE the move Abs is complete