Programming  
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D  Page D-115 
8 
9 
10 
11 
 
B 
C 
D 
1 
2 
3 
4 
5 
6 
7 
E 
Parameter Descriptions 
TRIPPED  
PREF: 92.13  Default: FALSE  Range: FALSE / TRUE  
Indicates that there is a latched trip present. 
RUNNING  
PREF: 92.14  Default: FALSE  Range: FALSE / TRUE  
Indicates that that the Drive is in the enabled state. 
JOGGING  
PREF: 92.15  Default: FALSE  Range: FALSE / TRUE  
Indicates that the Drive is in the JOG mode. 
STOPPING  
PREF: 92.16  Default: FALSE  Range: FALSE / TRUE  
Indicates that the Drive is stopping. 
OUTPUT CONTACTOR 
PREF: 92.17  Default: FALSE  Range: FALSE / TRUE  
Output to be used to drive an external contactor in the motor output. This contactor is normally closed unless a Trip condition 
has occurred or the Drive goes into the re-configuration mode. 
SWITCH ON ENABLE 
PREF: 92.18  Default: FALSE  Range: FALSE / TRUE  
Sometimes referred to as READY TO SWITCH ON, this parameter indicates that the Drive will accept a run command. 
SWITCHED ON  
PREF: 92.19  Default: FALSE  Range: FALSE / TRUE  
Run accepted. Waiting for CONTACTOR CLOSED and any motor deflux delay to be completed 
READY  
PREF: 92.20  Default: FALSE  Range: FALSE / TRUE  
Indicates that the Drive’s power stack is operable and the Drive will run if enabled. 
SYSTEM RESET  
PREF: 92.21  Default: FALSE  Range: FALSE / TRUE  
TRUE for a single block diagram execution cycle after the Drive enters either RUN or JOG mode.