EasyManua.ls Logo

Parker Hauser COMPAX-M Series - S30; S10

Parker Hauser COMPAX-M Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Object index
Interbus-S
26
2.5.2 S30
Error message.
This object contains the error number of the current error and the last occurring error.
If the error number of the current error = 0, there is no error.
Object Description
Index
0x5fd7
Symbol
S30
Length
1
Access groups
0
Object code
Array
Elements
2
Password
0
Data type
Unsigned8
Access rights
Read all
PD Map
Not possible
Data Description
Sub-index Assignment Sub-index Assignment
1 Error number of current error 2 Error number of last error
2.5.3 S6
Temperature of the power output stage.
Object Description
Index
0x5fde
Symbol
S6
Length
2
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned16
Access rights
Read all
PD Map
Not possible
Data Description
Unit
degrees Celsius
Resolution
1
0.1°C
2.5.4 S10
COMPAX operating hours
Object Description
Index
0x5fdb
Symbol
S10
Length
4
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned32
Access rights
read all
PD Map
Not possible
Data Description
Unit
Hours
Resolution
1
0.1 h