2. Object index
Interbus-S
26
2.5.2 S30
Error message.
This object contains the error number of the current error and the last occurring error.
If the error number of the current error = 0, there is no error.
Object Description
Index
0x5fd7
Symbol
S30
Length
1
Access groups
0
Object code
Array
Elements
2
Password
0
Data type
Unsigned8
Access rights
Read all
PD Map
Not possible
Data Description
Sub-index Assignment Sub-index Assignment
1 Error number of current error 2 Error number of last error
2.5.3 S6
Temperature of the power output stage.
Object Description
Index
0x5fde
Symbol
S6
Length
2
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned16
Access rights
Read all
PD Map
Not possible
Data Description
Unit
degrees Celsius
Resolution
1
0.1°C
2.5.4 S10
COMPAX operating hours
Object Description
Index
0x5fdb
Symbol
S10
Length
4
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned32
Access rights
read all
PD Map
Not possible
Data Description
Unit
Hours
Resolution
1
0.1 h

Table of Contents

Other manuals for Parker Hauser COMPAX-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Hauser COMPAX-M Series and is the answer not in the manual?

Parker Hauser COMPAX-M Series Specifications

General IconGeneral
BrandParker
ModelHauser COMPAX-M Series
CategoryController
LanguageEnglish

Related product manuals