2. Object index
Interbus-S
62
2.11.7 CAM_MEM_P
Special command for COMPAX XX70.
Set and read curve memory pointer.
Object Description
Index
0x5fca
Symbol
CAM_MEM_P
Length
2
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned16
Access rights
Read/write all
PD Map
Not possible
Data Description
Data format
Binary
Unit
Curve memory number
Value range
1 ... 5460
Resolution
1
2.11.8 CAM_MEM
Special command for COMPAX XX70.
Read and write the curve memory.
The curve memory number is defined by the current value of the curve memory pointer (CAM_MEM_P).
The curve memory pointer is automatically incremented after this object is accessed.
Object Description
Index
0x5fcb
Symbol
CAM_MEM
Length
3
Access groups
0
Object code
Simple var.
Password
0
Data type
Octet string
Access rights
Read/write all
PD Map
Not possible
Data Description
Data byte
123
Meaning
Record memory contents
Assignment
MSB ... LSB
2.11.9 VX
Enter or read COMPAX variable.
The corresponding variable is selected using the Sub-index (Sub-index = variable No.).
Sub-index = 40 addresses variable 0 of the COMPAX, with which all variables can be set to the same value.
Object Description
Index
0x5fcd
Symbol
VX
Length
4
Access groups
0
Object code
Array
Elements
40
Password
0
Data type
Integer32
Access rights
Read/write all
PD Map
Not possible

Table of Contents

Other manuals for Parker Hauser COMPAX-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Hauser COMPAX-M Series and is the answer not in the manual?

Parker Hauser COMPAX-M Series Specifications

General IconGeneral
BrandParker
ModelHauser COMPAX-M Series
CategoryController
LanguageEnglish

Related product manuals