3. DRIVECOM-PROFILE 22, from COMPAX Software-Version 3.01
Interbus-S
80
Status Description
NICHT-EINSCHALTBEREIT:
!
Self-test is running
!
Initialisation is running
!
Drive function is disabled
!
All functions are disabled
EINSCHALTSPERRE:
!
Software/hardware initialisation is terminated
!
Communication via all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (motor dead)
!
Display shows 'OFF'
EINSCHALTBEREIT:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (motor dead)
!
Display shows 'OFF'
EINGESCHALTET:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled (but motor has current)
!
Display shows 'run'
BETRIEB-FREIGEGEBEN:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is enabled (motor has current)
!
Display shows 'run'
SCHNELLHALT-AKTIV:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive implements the STOP function (motor has current)
!
Display shows 'run'
STÖRUNG:
!
Communication through all interfaces is enabled
!
Modifications to parameters, variables, records is possible
!
Drive function is disabled
!
Display shows 'Exx'
STÖRUNGSREAKTION:
!
Error handling only, no static device status