AS-i EtherNet/IP Gateway
Operating in Advanced Display Mode
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Issue date - 24.4.2007
37
Afterwards the test is started by confirming the menu entry "Test".
After finishing the test all relevant informations is displayed for the tested slave.     
A successful test is displayed with "OK" below the address of the tested slave.
The following information are displayed:
• Address of the tested slave
• Existing errors are indicated
• Binary inputs (digital inputs), see also “Binary input“, chapter 7.7.3
• Binary outputs (digital outputs), see also “Binary outputs“, chapter 7.7.4
• Analog inputs, see also “Analog inputs“, chapter 7.7.5
• Analog outputs, see also “Analog outputs“, chapter 7.7.6
• Param (actual parameters), see also “Parameter“, chapter 7.7.7
• Perm Param (projected parameters), see also “Permanent Param (projected 
parameter)“, chapter 7.6.7
• Config (actual configuration), see also “Actual Config (actual configuration)“, 
chapter 7.8.4
• Perm Conf (projected configuration), see also “Permanent Config (projected 
configuration data)“, chapter 7.6.8 
SLAVE TEST TOOL
SLAVE ADR     21A
TEST
SLAVE 15 OK
BINARY INPUTS
         0 1
BINARY OUTPUTS
 0 1
ANALOG INPUTS
0  +17898
1 +32767 OVERFL
ANALOG OUTPUTS
0 +1789
1 +2500
PARAM  F
PERM PARAM  F
CONFIG 7FFE
PERM CONF  7FFE