8.3.4.8 Get list of peripheral faults (GET_LPF)
With this call, the list of peripheral faults (LPF) signaled by the AS-i slaves is read 
out from the AS-i master. The LPF is updated cyclically by the AS-i master. If and 
when an AS-i slave signals faults of the attached peripherals (for example broken 
wire) can be found in the description of the AS-i slave.
8.3.4.9 Get list of offline Slaves (GET_LOS)
With this call, the list of slaves causing the offline phase when a configuration error 
occurs in being read out (List of Offline Slaves, LOS).
The user can choose the reaction of the master when a configuration error occurs. 
The master can be switched off line when an important slave causes a configura-
tion error; less important slaves can send an error to the host, AS-i however will 
not be switched offline.