83
Meaning of bit B:
B = 0Single AS-i slave or A-slave
B = 1B-slave
8.3.5.5 Set permanent configuration (SET_PCD)
This call sets the following configuration data for the addressed AS-i slave:
I/O configuration
ID code
Extended ID1 code
Extended ID2 code
The configuration data are stored permanently on the EEPROM of the AS-i/Ether-
Net/IP gateway and are used as the expected configuration by the AS-i master in
the protected mode. The configuration data are specified by the manufacturer of
the AS-i slave.
If the addressed AS-i slave does not support an extended ID code 1/2, the value
F
hex
must be specified.
When this command is executed, the AS-i master changes to the offline phase and
then changes back to the normal mode (warm restart).
This command can only be executed in the configuration mode.
Meaning of bit B:
B = 0Single AS-i slave or A-slave
B = 1B-slave
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
128
16
2T result
3 xID2 xID1
4ID I0
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
125
16
2T circuit
3 B slave address
4 xID2 xID1
5ID I0
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
125
16
2T result

Table of Contents