40-6
Servicing Safety & Precautions
4. Connect the welder ground cable clamp directly
to the member to be welded as close as
possible to the weld.
5. If arc-welding work is involved in any repair
operation, make sure that the current does
not pass through any bearings, hydraulic
components, electrical components and ground
straps.
6. Do not use electrical components, the
electronics control module or electrical ground
stud for grounding the welder.
7. Protect any wiring and electrical or hydraulic
components from welding debris or splatter.
8. Disconnect engine management system as
described in any welding instruction label inside
the engine canopy.
9. Use standard welding techniques to weld the
materials together.