2.4 Connections
VIBSCANNER 2 features an analog measuring channel, a charge connection, and an in-
terface for data exchange via USB. All connections are protected against humidity and con-
tamination using flexible cover caps.
Charge socket (left) and multipole analog measuring channel (analog IN, right) at the bottom of the
device.
Micro USB connection for data exchange.
2.4.1 Analog IN
The analog measuring channel is used to connect vibration sensors. A specifically tagged
multipole sensor cable is available for every sensor type (e.g., CLD, IEPE, triaxial, etc.).
WARNING!
Severe injuries due to drawing in of the sensor cable possible during meas-
urements on a running machine. A predetermined breaking point in the cable
length triggers when the cable connection to the measuring device is drawn in.
Always use the provided safety release cable between measuring device and
sensor cable.
20 Edition: 11.2017
2 - Description