5.1 Technical data
Parameter VIBSCANNER 2
Measuring channel, analog
Z channel
(0 ... 50 kHz)
-20 .. +20 V, input impedance: 78 kOhm
IEPE
Linedrive
X/Y channel
(0 ... 10 kHz)
-20 .. +20 V, input impedance: 78 kOhm
IEPE
Dynamic range 109.5 dB (total)
Sampling rate up to 131 kHz per channel
Signal processing 3 x 24 bit ADCs
Measuring range/
Accuracy
Vibration acceleration: dependent on used sensor
Shock pulse: -10 dBsv to 80 dBsv +/- 2 dBsv
Fulfilled standard DIN ISO 2954:2012 (2-1 kHz, 10 Hz -1 kHz, 10-10 KHz)
Display
Type Capacitive touchscreen
Optically bonded for high contrast and increased shock res-
istance
Active area 95 x 54 mm (3 3/4 x 2 1/8”)
Size 10.9 cm (4 1/3“)
Color depth 16 million colors
Viewing angle < 140°
Operation Multi touch gesture control
Glove-compatible
Illumination Background lighting, adjustable
Ambient light sensor Yes
Supply
Type Li ion rechargeable battery
Rated voltage 7.2 V
Energy density 72 Wh