EasyManua.ls Logo

Radwin 2000 D+ - Page 115

Radwin 2000 D+
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN2000D+UserManual Release3.6.00 89
MoreontheThresholds Chapter8
Databecomesinvalidatedfollowingareset.Intheexamplebelow,theSlaveODUwasreset
shortlyafter08:45.Alldatapriortothattimebec omesinvalidated.Theonlyvaliditemsare
therecordingsfollowingtheresync.
Figure84:HBS‐PerformanceMonitoringreport‐Showinginvaliddata
UsetheSavebuttontostorethecurrentdatatoafileandtheClearbuttontodeletecurrently
storedperformancedata.
8.4.2MoreontheThresholds
RSLThresholds
TwoRSLThresholdscanbedefined.Theyareusedasanindicatorofproblemsintheradio
channel.YoucanchecktheRSSfromtheLinkBudgetCalculatorresultsduringinstallation.
Valuesof‐5dBand‐8dBfromthecurrentRSSaretypical.
TSLThreshold
Acounterismaintained,ofthenumberofsecondintervalsduringwhichTxpowerexceeds
thisthreshold.
BBERThreshold
TheBackgroundBlockErrorRatioismeasuredasa percentage .Thethresholdcanbesetfrom
0.1%upto50%.
An8%thresholdisrecommended.Iftherearenoproblemsduringtheinterval,thenforthat
threshold,therecommendedBBERvalueshouldbe0.Sincethesystemprovidesalossless
Ethernetservice,thereisthroughputdegradationincaseofinterference.Thedegradationis
proportionaltotheBBER.
AboveTraffic
Thresh
Thresholdsetin
Figure 82
Secondscountwhenactualtrafficexceededthe
threshold
ActiveSeconds
Thenumberofsecondsthattheconfigured
Ethernet
serviceisactive
Table82:HBSPerformanceMonitoringFields(Continued)
ColumnHeading
Abbreviation
Meaning
Description

Table of Contents