EasyManua.ls Logo

Radwin 2000 D+ - Table 11-1 External Pulses

Radwin 2000 D+
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN2000D+UserManual Release3.6.00 1111
SyncStatusMessagesandColorCodes Chapter11
11.4SyncStatusMessagesandColorCodes
ThepossibleExternalPulsesconditionsareshowninthefollowingtable:
Table111:ExternalPulseStatus
HSSSyncStatus Meaning
Color
code
Generating
ODUisHSMandgenerate sthesyncpulse
Green
Detected
ODUisHSCanddetectsthesyncpulse
Notdetected
ODUisindependent
Generatingand
detected
HSM,butotherHSMpresent
Orange
Generatingand
Improperly
Detected
RADWIN2000D+orRADWIN5000isHSM,butdetectsa
Airmux200orRADWIN2000HSMsignalthatisnotRFPE
Notdetected
HSCbutnoHSMpresent
Improperly
detected
HSCbutHSMpulsedoesn’tfittheHSCasconfigured.Occurs
onlyforRADWIN2000D+andRADWIN5000,whichstop
transmitting.
Red

Table of Contents

Related product manuals