6.2 Status Codes
The PMP status code is displayed in a series of hexadecimal characters representing
the status of different alarm conditions. The value '1' indicates the associated condition
is active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation.
It is recommended to use a scientific calculator that supports binary notation (e.g.,
Windows on-screen calculator). Set the mode for Hex and enter the status code.
Change the mode to binary and match active bits (1) to the PMP Status Codes table.
For example, if 'Radio Over Temperature' bit 1 and 'PLL Error' bit 4 were active, the
status code value would be Hex '12' (binary 1 0010).
Table 36: Diag. - PMP Status Code Bits
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
9
8
7
6
5
4
3
2
1
0
Table 37: Diag. - PMP Status Codes
Bit
Description
1
Radio over-temperature
4, 5, 6
PLL Errors
8
Firmware Error
16
No Ethernet packets received by the wireless MAC
17, 18, 19, 20, 21, 22,
23, 24, 25, 26, 27, 28
MAC Internal Errors

Table of Contents