6.3.2 Test Configuration Changes
The operator can use the reboot and apply functions to test changes to the configuration
that may result in loss of the wireless link. Use the following steps to test new setup
values for a five minute period and then restore the last saved configuration.
1. Make all necessary editing changes to the configuration.
2. Issue the command 'reboot 300'. This will set a timer to reboot the RDL-3000 in five
minutes (5 x 60 seconds). A longer or shorter time can also be specified.
3. Issue the 'apply' command to activate all edited changes.
4. If connectivity to the RDL-3000 is lost, wait 5 minutes for the unit to reboot
automatically and restore the previous settings.
5. If the setting are satisfactory, use 'save config' to save these settings and 'reboot 0'
to cancel the timed reboot operation.
6.4 Factory Default Settings
Use the Web interface (click Factory Defaults in main menu) or the CLI interface (save
defaultconfig) to restore the RDL-3000 to a known state.
Table 38: Diag. - Factory Default Settings
"Public". read