RL78/F13, F14 CHAPTER 15 SERIAL ARRAY UNIT
R01UH0368EJ0210 Rev.2.10 1004
Dec 10, 2015
Figure 15-149. Flowchart of Data Transmission
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0, 1), r: IIC number (r = 00, 01, 10, 11),
mn = 00, 01, 10, 11
Starting data transmission
Data transmission
completed
Transfer end interrupt
g
enerated?
No
Yes
Writing data to the SDRmn
register
No
Yes
ACK reception error
St
op con
diti
on genera
ti
on
Data transfer completed?
Yes
No
Address field
transmission completed
Parity error (ACK error) flag
PEFmn = 1 ?