RL78/F13, F14 CHAPTER 17 LIN/UART MODULE (RLIN3)
R01UH0368EJ0210 Rev.2.10 1219
Dec 10, 2015
The aforementioned timeout time is a time greater than the TFRAME_MAX of LIN Specification Package
Revision 1.3 on classic selection, or the TFRAME_MAX of LIN Specification Package Revision 2.x on
enhanced selection.
[Response timeout]
Timeout time = (number of data bytes + 1) × 14 [Tbit]
Caution The error status is cleared when another communication is started, when cleared by software, or
after transition to LIN reset mode.