3-56 Monitoring and Diagnostics VisualMotion 9 Troubleshooting Guide
DOK-VISMOT-VM*-09VRS**-WA02-EN-P
!30 Invalid I/O Register or Bit Number
The I/O register mnemonic is invalid or a register number greater than the
maximum number of registers was sent.
!31 Invalid Table Index
The ABS, REL, or EVT table name was incorrect, or the index number
was greater than the maximum number of points or events.
!32 Communication Port Error
The serial port receive buffer has overflowed. Make sure communication
is set to half-duplex.
!33 Invalid Data Format
The format of the data received by the control is invalid (e.g., non-digits
are sent in a decimal number).
!34 Active program can't be deleted
The active program cannot be deleted at any time. To delete an active
program, first stop program and then delete.
!35 Parameter mode is required
The action requested can only be performed in Parameter Mode.
!36 Invalid Event Number
The event number selected in the ABS or REL point table is out of the
range of the total number of events.
!37 Invalid Event Function
The function name selected in the event table does not exist on the
control or is not defined as an event function.
!38 Program file version mismatch
The version of the file system on the control does not match that of the
downloaded file. Upgrade to the latest version of VisualMotion Toolkit.
!39 Can't activate while program running
A new program cannot be activated unless all user tasks are stopped.