VisualMotion 9 Troubleshooting Guide Monitoring and Diagnostics 3-57
DOK-VISMOT-VM*-09VRS**-WA02-EN-P
!40 No programs are active
No programs are active on the control. Download a program to the
control’s memory.
!41 System Error: pSOS #XXXX
This is an internal system error. Call Bosch Rexroth Service for
assistance.
!42 Mapper: invalid operator
An invalid Boolean operator was found in I/O Mapper when it was sent to
the control.
!43 Mapper: too many operations
The maximum number of Boolean operations allowed by the control I/O
Mapper has been exceeded.
!44 Mapper: invalid register
A register exceeds the maximum number of registers or is 0.
!45 Mapper: invalid bit or mask
The bit number or mask sent exceeds 16 bits.
!46 Mapper: register is read-only
An assignment to a read-only register or bit was made (e.g., attempting to
write to a control status register).
!47 Invalid Unit Number
The unit number (second character in string) is not a number between '1'
and 'F' or an ASCII space character.
!50 Invalid Download Block
The block sent during a program download is incorrect in length or is not
in hexadecimal format.
!52 Invalid Axis
The parameter set for the requested axis does not exist. Either this axis
is disabled or the control does not support this number of axes.