VisualMotion 9 Troubleshooting Guide Monitoring and Diagnostics 3-61
DOK-VISMOT-VM*-09VRS**-WA02-EN-P
!88 No Virtual Master are currently active
The Virtual Master number being transmitted to the control by way of
serial communications is currently not active or is invalid. Valid Virtual
Master numbers are 1 and 2. Verify that the request number is existing
and active in the user program.
!89 Unsupported Parameter for mapping
The Fieldbus mapping list being transmitted to the control by way of serial
communications contains a parameter(s) that is not supported as a
Fieldbus mapping object.
!90 Invalid variable for mapping
The Fieldbus mapping list being transmitted to the control by way of serial
communications contains invalid variables (program float or integers) that
are not present in the active user program.
!91 CAM build: float table start index #
The CAM build float table start index (starting float variable) being
requested from the control by way of serial communications is less than 1
or greater than the allowable range in the sizing instruction.
!92 CAM build: float table end index #
The CAM build float table end index (end float variable) being requested
from the control by way of serial communications is beyond the maximum
range (number) in the sizing instruction.
!93 CAM build: float table size #
The CAM build float table size (range of float variables) is larger than or
out of range of the allowed number of floats in the sizing instructions.
!96 Duplicate Message Sequence Number (MSN)
This communication error is reserved for future development.
!97 Requested operation prohibited from network
This communication error is issued when an attempt is made to access a
control, across the Ethernet network, when access is not allowed.
Network access to a control is configured using control parameter
C-0-0405.
!99 Request in Progress
This communication error is issued when a second request is made to
flash global variables, using C-0-0082, before the initial request is done.