3-60 Monitoring and Diagnostics VisualMotion 9 Troubleshooting Guide
DOK-VISMOT-VM*-09VRS**-WA02-EN-P
!80 Invalid Object Number
The Fieldbus object number being transmitted to the control by way of
serial communications has become corrupted and is in an invalid format.
Fieldbus object numbers must always begin with a 5, e.g., 5F02.
!81 Invalid Mapping(s)
The Data Type selected in the Fieldbus Mapper is invalid. Fieldbus object
number can be mapped to a Variable, Register, Card parameter, Axis
parameter, or Task Parameter. The Data Types mentioned above
becomes an invalid mapping if the type being selected can not be
mapped or is read only. This will normally occur when mapping object
numbers to parameters.
!82 Write protected by password
The SERCOS parameter being modified is password protected. This
password protection is reserved for Bosch Rexroth Service personnel.
!83 Valid ELS Group numbers are 1 through 8
The ELS Group number being transmitted to the control by way of serial
communications has become corrupted and is an invalid. Valid ELS
Group numbers are 1 through 8.
!84 ELS Group is not currently active
The ELS Group number being transmitted to the control by way of serial
communications is currently not active or is invalid. Valid ELS Group
numbers are 1 through 8. Verify that the request number is existing and
active in the user program.
!85 Data not limited to a specific ELS Master
The data being requested from the control by way of serial
communications is not specific to any one ELS master.
!86 No ELS Masters are currently active
The ELS Master number being transmitted to the control by way of serial
communications is currently not active or is invalid. Valid ELS Master
numbers are 1 through 6. Verify that the request number is existing and
active in the user program.
!87 Valid Virtual Master numbers are 1 and 2
The Virtual Master number being transmitted to the control by way of
serial communications has become corrupted and is invalid. Valid Virtual
Master numbers are 1 and 2.