SERVICE PROGRAM MODE 26 January, 2001
5-34
SP5 Mode Number Function and [Setting]
5828* 36 Network AppleTalk
Module Setting
Sets the AppleTalk module for the network.
2: EtherTalk Phase2
37 Network NetNo Setting
(AppleTalk)
Sets the NetNo of AppleTalk network.
38 Network Object Name
Setting (AppleTalk)
Sets the object name of AppleTalk network.
39* Network AppleTalk Type
Setting
Sets the AppleTalk type for the network.
40 Network Working Zone
Setting (AppleTalk)
Sets the AppleTalk working zone for the network.
47* Network Job Analysis
Timeout Setting
(Centronics)
Sets the Centronics job analysis timeout for the
network.
[0~4200 s / 3 s / 1 sec. step]
48* Network Job Timeout
Setting (Centronics)
Sets the Centronics job timeout for the network.
[0~4200 s / 0 s / 1 sec. step]
49*
Network Noise Cancel
Setting (Centronics)
Sets the noise cancel level for the network.
[4~7 / 4 / 1 clock per step]
50* Network 1284
Compatibility Setting
(Centronics)
Switches Centronics IEEE1284 compatibility
on/off for the network.
0: Disabled, 1: Enabled
Selecting “0” disables bi-directional data
transmission.
51* Network Data Transfer
Speed Setting
(Centronics)
Sets the Centronics transfer speed for the
network.
0: SLOW, 1: FAST
If you select “0” there will be a 120
µ
s delay from
the STP signal to the data transfer. (With 1: FAST
there is no delay.)
52* Network ECP Setting
(Centronics)
Switches the ECP setting for Centronics off/on.
0: Disabled, 1: Enabled
With “1” selected, SP5-828-050 must be enabled
for 1284 mode compatibility.
53* Network Transmission
Speed Setting
Selects the Ethernet transmission speed.
[0x00~0x03 / 0x00 / 0x01 step]
Bit1 Bit2 Speed
0 0 Auto Sense
0 1 10Base-T
1 0 100Base-Tx
11Auto
5833 Job Log Transfer On/Off
Setting
Switches the job log transfer on/off for Poplar
server.
0: Off (disable), 1: On (enable)
5834 Enable Operation Panel
Image Settings
Enables and disables the operation panel read
(dump) feature. After powering on the machine,
set this option to 1 to enable this feature.
0: Off (disable), 1: On (enable)
To reset the machine to 0, the machine must be
turned off and on again. Selecting 0 for this option
without cycling the power off and on does not
restore the default setting (0).