EasyManua.ls Logo

Ricoh A-P4 - SC Code Descriptions

Ricoh A-P4
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The power LED lights or flashes while machine is communicating with the network server, or while the
machine is accessing the hard disk or memory.
302 D
Charge roller current leak
Charge roller damaged
HVPS pack defective
PCU harness defective or disconnect-
ed
Charge leak detected when charge was
applied to the charge roller. The upper limit
of PWM duty was detected (65%) for 60
ms.
304 D
Charge roller current correction error
Charge roller defective due to exces-
sive wear
The charge roller bias correction was done
twice but maximum charge was not detect-
ed even after the maximum charge roller
bias (–2kV) was applied to the roller.
321 D
F-Gate error
BICU board defective
PCI harness between the controller
board and the BICU defective or dis-
connected
No laser signal. The laser write signal (F-
GATE) did not go to LOW within 60 sec.
after the copy paper reached the registra-
tion sensor.
322 D
Synchronization error Laser synchronization board connec-
tors or harness loose, disconnected,
or damaged
Laser synchronization board defective
or out of position
LD drive board defective
The synchronization signal was not issued
within 500 ms after the LD fired while the
polygon motor was turning at the pre-
scribed number of revolutions.
323 D
LD drive current too high LD unit defective (not enough power,
due to aging)
Poor connection between the LD unit
and the BICU board
BICU defective
The LD drive board output to the LD ex-
ceeded 100 mA .
327 D
LD unit home position error 1
LD unit HP sensor/harness defective
4. Troubleshooting