543 A
Fusing overheat error (software detection) Check harnesses and connectors of
PSU, IOB, BICU
PSU defective
IOB defective
BICU defective
Fusing thermistor defective or wrong
type
A fusing temperature of over 230°C
(446
o
F) is detected for 5 seconds by the
fusing thermistors at the center or at either
end of the hot roller.
544 A
Fusing overheat error (hardware circuit de-
tection)
Check harnesses and connectors of
PSU, IOB, BICU
PSU defective
IOB defective
BICU defective
Fusing thermistor defective or wrong
type
The dual monitoring circuitry of the BICU
detected temperature above 250
o
C
(482
o
F) and tripped the relay circuit off.
545 A
Fusing lamp remains on
One or both thermistors out of posi-
tion.
After warm-up the fusing lamp remained at
full power for 10 sec. (center) and 15 sec.
(ends) without the hot roller rotating.
547 D
Zero cross signal error
PSU defective
Noise on the ac power line
One of the following occurred:
1. The fusing relay remained off for 50 ms
after power on and continued to re-
main off after the after 3 attempts to
detect the zero-cross signal.
2. During 11 zero-cross signal detec-
tions, two zero-cross signal detections
were below 44 Hz.
3. The zero-cross signal could not be de-
tected within 3 sec. after the fusing
relay switched on.
548 A
Fusing unit installation error
Fusing unit is not installed
Service Call Conditions