A break (low) signal was received from the
finisher.
BICU board and finisher main board
connection defective or loose
Finisher main board defective
BICU board defective
623 D
Communication timeout error between
BICU and paper tray unit
Serial line connecting BICU and pa-
per tray unit unstable
External noise
BICU board and paper tray main
board connection defective or loose
Paper tray main board defective
BICU board defective
The BICU cannot receive a response within
100 ms after 3 attempts after sending data
to the paper tray unit.
624 D
Communication break error between BICU
and paper tray unit
Serial line connecting BICU and pa-
per tray unit unstable
External noise
BICU board and paper tray unit con-
nection defective
Optional paper tray unit interface
board defective
BICU board defective
The BICU cannot communicate with the pa-
per tray unit due to receiving a break signal.
626 D
Communication timeout error between
BICU and LCT
Serial line connecting BICU and LCT
unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
The BICU cannot receive a response within
100 ms after 3 attempts after attempting to
communicate with the LCT.
627 D
Communication break error between BICU
and LCT
Serial line connecting BICU and LCT
unit unstable
External noise
BICU board and LCT main board
connection defective or loose
The BICU cannot communicate with the LCT
unit due to receiving a break signal.
Service Call Conditions