COPIER INSTALLATION
B089/B093 3-8 SM
3. Open the front cover [A].
4. Remove the red tag [B] and toner seal [C], then peel the sealing tape [D] off to
install the developer.
5. Raise the toner bottle holder lever [E], push lever [F] down, and pull the toner
bottle holder [G] out.
6. Shake the toner bottle [H] well.
NOTE: Do not remove the toner bottle cap [I] until after shaking.
7. Unscrew the bottle cap [I] and insert the bottle into the holder.
NOTE: Do not touch the inner bottle cap [J].
8. Reposition the holder and press down the holder lever to secure the bottle.
9. Open the right cover.
10. Rotate the green fusing pressure lever [K] to the up position.
B089I500.WMF