SERVICE CALL CONDITIONS
SM 7-13 B089/B093
Trouble-
shooting
Code No. Symptom Possible Cause
Address Book Data Error 870 B
Address book data stored on the hard
disk was detected as abnormal when it
was accessed from either the operation
panel or the network.
Software defective
HDD defective
FCU Flash ROM Error 871 D
The address book written into the flash
ROM mounted on the FCU is detected
as defective.
Flash ROM device defective
Replace flash ROM on the MBU
Email Receiving Data Error 872 B
Machine detects an HDD error during
warm-up.
Email(s) previously received by the
machine and stored in the hard drive
may contain damaged data.
This can be deleted by executing
SP5832-007, however note that
doing so will also delete all other
received emails.
Defective HDD
Email Sending Data Error 873 B
Machine detects an HDD error during
warm-up.
l Email(s) previously sent by the
machine and stored in the hard drive
may contain damaged data. This can
be deleted by executing SP5832-
008, however note that doing so will
also delete all other sent emails, as
well as initialize the sender’s user
name/password and administrator
Mail address.
Defective HDD
File Format Converter (MLB) Error 880 D
A request for access to the File Format
Converter (MLB -Media Link Board)
was not answered within the specified
time.
MLB defective
HD access error 865 D
The hard disk detected an error.
Replace the controller board
Electronic total counter error 900 D
The value of the total counter has
already exceeded 9999999
Replace the NVRAM on the controller
board
Mechanical total count error 901 D
The SBCU board cannot receive the
mechanical total count data.
Mechanical total counter defective
Printer Error 1 920 D
An internal application error was
detected and operation cannot
continue.
Software defective
Insufficient memory
Network File Error 925 D
The file that manages NetFile is
corrupted and operation cannot
continue.
Software defective
Files on the HDD corrupted
F-gate error at write request 951 B
After the IPU receives an F-gate signal,
it receives another F-gate signal.
Download controller firmware
SBCU board defective