Technical Bulletin PAGE: 5/16
Model: Taurus-C1/P1 (D074/D075/M044) Date: 10-Apr-12 No.: RD074060
1-3. Possible problems involving skew correction
(a) Skew Variation
1. Confirm secure fastening of the 2 screws to prevent the adjustor plate from loosening.
If fastening the screws cannot securely fix the plate, insert a material, for instance an
OHP transparency to stabilize the plate.
2. Increase the values in SP1004 (Registration Buckle Adj) and SP1005 (Reg Buckle Adj;
Thick) to reduce skew. (The effect varies depending on the paper weight).
(b) Jam 97
Do the following if the adjustor plate is currently set to a value smaller than “– 2”.
1. Set the adjustor plate to a value between – 2 and +5.
2. Replace the shift roller with the modified one, D0742760. (See the next page.)
Reason
Jam97 is caused by interference between the registration gate and the shaft of the shift
roller, which occurs if the adjustor plate is set to a value smaller than -2 and the unit is
installed with an ‘unmodified shift roller’.