Technical Bulletin PAGE: 4/6
Model: Taurus C1/P1 (D074/D075/M044)
Date: 27-Jan-13
No.: RD074112
3. Insert the cleaning tool into the doctor gap from the corner without the angled tab. The tab
scrapes off the toner/dust adhered to the doctor blade as you slide the tool across the doctor
gap.
4. Slide the tool from right to left. Keep it level as you slide the tool, to prevent scratches on the
development roller.