R&S
®
ZVA/ZVB/ZVT CALCulate
1145.1084.12 6.51 E-6
SCORr14
Source match 3 (S33)
SCORr15
Reflection tracking 3 (S33)
SCORr16
Isolation 3 (S31)
SCORr17
Load match 3 (S31)
SCORr18
Transmission tracking 3 (S13)
SCORr19
Isolation 1 (S13)
SCORr20
Load match 1 (S13)
SCORr21
Transmission tracking 1 (S13)
SCORr22
Isolation 3 (S32)
SCORr23
Load match 3 (S32)
SCORr24
Transmission tracking 3 (S32)
SCORr25
Isolation 2 (S23)
SCORr26
Load match 2 (S23)
SCORR27
Transmission tracking 2 (S23)
Use the generalized command [SENSe<Ch>:]CORRection:COLLect:CDATa to read or write
error terms for arbitrary analyzer ports.
CALCulate<Ch/Tr>:DATA:NSWeep? SDATa,<Trace_Hist_Count>
Reads the response values of a trace acquired in single sweep mode (INITiate<Ch>:CONTinuous
OFF).
<Ch/Tr>
Channel number used to identify the active trace.
SDATa
Read unformatted sweep data (fixed parameter): Returns the
real and imaginary part of each measurement point (2 values
per trace point irrespective of the selected trace format).
<Trace_Hist_Count>
Number of sweep to be read.
Range [def. unit]
1 to sweep count defined via [SENSe<Ch>:]SWEep:COUNt [–]
*RST value
SCPI, Command
Types
Device-specific, query only
Example:
SWE:COUN 10
Define the number of sweeps (10) to be measured in single
sweep mode.
INIT:CONT OFF; INIT
Activate single sweep mode and start a single sweep in
channel no. 1.
CALC:DATA:NSW? SDAT,5
Query the results of the 5
th
sweep.