Multimeter Measurements
R&S
®
Scope Rider RTH
151User Manual 1326.1578.02 ─ 12
Figure 7-5: Four-voltmeter-view
1 = Channel measured by the voltmeter
2 = Bargraph displaying the measured value
3 = Measurement ranges of active channels
In meter mode, the keys behave different from scope mode:
The vertical [RANGE] and [POS] keys both adjust the measurement range of the
selected channel.
The [MEAS] key opens the "Meter" menu.
The following keys work as usual: [FILE],
, , [PRESET], [MODE], [BACK].
All other keys do not work.
Displaying voltmeters
To switch to one-voltmeter-view, use one of the following methods:
Tap the meter number as shown in Figure 7-5.
Turn the wheel to select a voltmeter, and press the wheel button to open it.
To view all 4 voltmeters, use one of the following methods:
Tap the highlighted number of the opened voltmeter as shown in Figure 7-4.
Press [BACK].
7.2.3 Running Voltmeter Measurements
1. Set up the channels for voltmeter measurements.
a) Select the "Vertical" menu.
Voltmeter (R&S
RTH1004)