HARMonic:THDType <THDType>
Parameters:
<THDType> THDF | THDR
THDF
The RMS amplitude (voltage or current) of the harmonics rela-
tive to the RMS amplitude of the fundamental component
THDR
The RMS amplitude of the harmonics relative to the RMS ampli-
tude of the input signal
*RST: THDF
15.6.3.2
Retrieving and Exporting Harmonic Results
You can export the harmonic results to a file, similar to waveforms (see Chapter 15.13,
"Documenting Results", on page 489).
HARMonic:EXPort:NAME............................................................................................... 371
HARMonic:EXPort:SAVE................................................................................................ 372
HARMonic:RESult<m>:CLIPping?................................................................................... 372
HARMonic:RESult<m>:FRQMissing?...............................................................................372
HARMonic:RESult<m>:FUNDamental?............................................................................ 373
HARMonic:RESult<m>:HARMonics<n>:ABSMagnitude:MAXimum?....................................373
HARMonic:RESult<m>:HARMonics<n>:ABSMagnitude:MINimum?.....................................373
HARMonic:RESult<m>:HARMonics<n>:ABSMagnitude[:CURRent]?...................................373
HARMonic:RESult<m>:HARMonics<n>:LIMCheck?.......................................................... 373
HARMonic:RESult<m>:HARMonics<n>:LIMit?.................................................................. 374
HARMonic:RESult<m>:HARMonics<n>:LIMViolation?....................................................... 374
HARMonic:RESult<m>:HARMonics<n>:PHASe?.............................................................. 375
HARMonic:RESult<m>:HARMonics<n>:RELMagnitude:MAXimum?....................................375
HARMonic:RESult<m>:HARMonics<n>:RELMagnitude:MINimum?.....................................375
HARMonic:RESult<m>:HARMonics<n>:RELMagnitude[:CURRent]?................................... 375
HARMonic:RESult<m>:HARMonics<n>[:FREQuency]?......................................................376
HARMonic:RESult<m>:LIMViolation?...............................................................................376
HARMonic:RESult<m>:NOHarmonics?............................................................................ 377
HARMonic:RESult<m>:NOResults?.................................................................................377
HARMonic:RESult<m>:RMS:MAXimum?..........................................................................377
HARMonic:RESult<m>:RMS:MINimum?...........................................................................377
HARMonic:RESult<m>:RMS[:CURRent]?.........................................................................377
HARMonic:RESult<m>:THD:MAXimum?.......................................................................... 378
HARMonic:RESult<m>:THD:MINimum?........................................................................... 378
HARMonic:RESult<m>:THD[:CURRent]?......................................................................... 378
HARMonic:EXPort:NAME <Name>
Defines the file name, file format and path to save the harmonic measurement results.
Parameters:
<Name> String with path and file name with extension .csv.