4
Part of
Practice
Fully Utilize the Media Heating System
81
Default Setting
[PRINT]: 40 °C (104 °F)
[DRYER]: 45 °C (113 °F)
Control of Media Heating System During Preheating
*Preheating: State that the main power and the sub power are switched on and is not lighted (state
that media loading is not completed)
Procedure
Press .
Press several times until the screen on the left appears.
Press
, and then .
Press .
Press to select setting.
MENU
The machine performs heating to the preset temperature at all times,
without lowering the temperature during preheating.
30 °C (86 °F)
The system keeps 30 °C (86 °F) during preheating.
OFF
The system switches the media heating system o during preheating.
Press to enable the setting.
Press to go back to the original screen.
Default Setting
[PREHEATING]: 30 °C (86 °F)
MENU
HEATER MENU
HEATER MENU
PREHEATING
PREHEATING
30 C MENU

Table of Contents