3
Maintenance
51
Maintenance that Should Be Performed Daily
Discard Discharged Fluid
The drain bottle collects discharged uid. Discard collected discharged uid
before the drain bottle becomes full. The screen appears when a certain
amount of discharged uid has collected in the drain bottle. Follow the
procedure below to discard the discharged uid.
Procedure
When the screen on the left appears, detach the drain bottle
and discard the discharged uid to empty it.
After discarding the discharged uid, you must promptly attach the drain
bottle to the machine.
Upper limit
Discard before this is
reached.
CAUTION
Before you detach the drain bottle, be sure to wait for the screen to display
"EMPTY DRAIN BOTTLE."
After discarding the discharged uid, promptly attach the drain bottle to
the machine.
Failing to follow this procedure may cause discharged uid to ow out of the
machine and spill, soiling your hands or the oor.
Press to display the screen on the left.
Press
to select [YES].
Press
.
The display goes back to the original screen.
EMPTY
DRAIN BOTTLE
EMPTY
DRAIN BOTTLE
W1200mm
SETUP SHEET
NOW EMPTY?
[YES] NO
If you select [NO] without discarding discharged uid:
This also allows you to go back to the original screen. The [EMPTY DRAIN BOTTLE] message disap-
pears temporarily. When a certain amount of discharged uid has been collected in the drain bottle,
the message appears again.
CAUTION
When the [EMPTY DRAIN BOTTLE] message appears on the
screen, discard discharged uid.
Repeatedly selecting [NO] without discarding the discharged uid may
cause it to spill out of the drain bottle, soiling your hands or the oor.